K3166i Universal Relay Test Set
(All-in-one design,complying IEC61850 SV & GOOSE)
Output Current: 6×35A@450VA max.
3×70A@850VA max.
Output Voltage: 7×310V@90VA max.
All-in-One design, Integrated IEC61850 SV & GOOSE, 6I+7V analog channels output, Inbuilt GPS and IRIG-B, and other advance functions.
1. Complied IEC61850-9-1, IEC61850-9-2, IEC60044-7/8, etc.
2. 100/1000Mbit Fiber ports for SMV and GOOSE simulations.
3. 6×35A & 7×310V independent high burden output channels.
4. 13 channels independent low-level signal outputs.
5. AC/DC measurement (8 channels inputs,class 0.1,0-600V/0-5A,auto range).
6. Transducer calibartion (class 0.02).
7. Energy meter calibration ( Mechanical & Electronic meters ).
8. Analog and Binary Transient Record.
9. Transient play back up to 3KHZ.
10. Light weight <18kg
11. Fully function KRT software testing modules.
12. 3-Years guarantee of free repair and life-long maintenance.
13. Free software upgrade.
Model | Current Outputs | Voltage Outputs | ||||
K3166i | 6×35A@450VA max / 3×70A@850VA max | 7×310V@90VA max | ||||
K3163i | 6×35A@450VA max / 3×70A@850VA max | 4×310V@124VA max | ||||
K3130i | 3×35A@450VA max | 4×310V@124VA max | ||||
K3166 | 6×35A@450VA max / 3×70A@850VA max | 7×130V@75VA max | ||||
K3163 | 6×35A@450VA max / 3×70A@850VA max | 4×130V@75VA max | ||||
K3130 | 3×35A@450VA max | 4×130V@75VA max |
Testing Items ANSI® No.
IEC61850 numerical IEDs relay & merge unit --
Distance protection relay 21
Synchronising or synchronism-check relays 25
Undervoltage relays 27
Directional Power relays 32
Undercurrent or underpower relays 37
Negative sequence overcurrent relays 46
Overcurrent/ground fault relays 50
Inverse time overcurrent/ground fault relays 51
Power factor relays 55
Overvoltage relays 59
Voltage or current balance relays 60
Directional overcurrent relays 67
Directional ground fault relays 67N
DC overcurrent relays 76
Phase-angle measuring or out-of-step protection relays 78
Automatic reclosing devices 79
Frequency relays 81
Motor overload protection relays 86
Differential protection relays 87
Directional voltage relays 91
Voltage and power directional relays 92
Tripping relays 94
Voltage regulating relays --
Overimpedance relays, Z> --
Underimpedance relays, Z --
Time-delay relays --
1. 13 Channels (6×35A & 7×310V) outputs, each output channels are independent and simultaneous.
2. Variable battery simulator, DC 0-350V, 140Watts max.
3. 13 Low-level channels outputs up to 8Vac/10Vdc max.
4. 0-600V / 0-5A AC/DC measurement in 0.1 class.
5. Graphical test modules and templates for testing of various relays.
6. Quick relay testing facility in Manual mode.
7. Shot/Search/Check, Point & Click testing.
8. RIO/XRIO import & export facility.
9. Switch on to fault test(SOTF).
10. Power system model for dynamic testing.
11. Inbuilt GPS and IRIG-B sync end-to-end testing.
12. Online Vector display.
13. Automatic test results assume.
14. Automatic test report creation.
15. Anti-clipping detect,wrong wiring connect alarm and self-protect, overload and overheat protection.
Voltage Outputs | ||||||
Output Range & Power | 7×310V ac (L-N) | 90VA max each | ||||
3×620V ac (L-L) | 180VA max each | |||||
3×350V dc (L-N) | 140W max each | |||||
Accuracy | AC:<0.03%Rd + 0.01Rg Typ. / <0.07%Rd + 0.03Rg Guar. | |||||
DC: ±10mV @<5V,±0.5% @ ≥5V | ||||||
Resolution | 1mV | |||||
Distortion | <0.05% Typ. / <0.1% Guar. | |||||
Current Outputs | ||||||
Output Range & Power | 6×35A ac(L-N) | 450VA max each | ||||
3×70A ac(2L-N) | 850VA max each | |||||
1×100A ac(6L-N) | 1200VA max | |||||
3×20A dc(L-N) | 300W max each | |||||
Accuracy | AC:<0.05%Rd + 0.02Rg Typ. / <0.15%Rd + 0.05Rg Guar. | |||||
DC: ±5mA @<1A,±0.5% @ ≥1A | ||||||
Resolution | 1mA | |||||
Distortion | <0.05%Typ. / <0.1% Guar. | |||||
13 Low-Level Channel Outputs | ||||||
Quantity | 13 Channels, 16 pin aviation socket | |||||
Voltage outputs range | AC 0-8V, DC 0-10V | |||||
Current outputs range | Nominal 2mA, 10mA max transient | |||||
Output Power | ≥0.5VA | |||||
Accuracy | (0.01~0.8 Vrms):<0.05% Typ. / <0.1% Guar. | |||||
(0.8~8 Vrms):<0.02% Typ. / <0.05% Guar. | ||||||
Resolution | 0.25mV | |||||
Distortion(THD%) | <0.05%Typ. / <0.1% Guar. | |||||
Frequency & Phase Angle | ||||||
Frequency Range | DC~1KHZ, 3KHZ transient | |||||
Frequency Accuracy | ±1ppm | |||||
Frequency Resolution | 0.001Hz | |||||
Phase Range | -360°~360° | |||||
Phase Accuracy | <0.05°Typ. / <0.1° Guar. 50/60Hz | |||||
Phase Resolution | 0.001° | |||||
IEC61850 Fiber & GOOSE Ethernet Ports (Optional Function) | ||||||
Fiber Ports | 2×100Base-FX Full Duplex,LC type
| |||||
Fiber Type | 62.5/125um (Multiple optical fiber, Orange Red) | |||||
Wavelength | 1310nm | |||||
Transmit Distance | >1Km | |||||
Indicator | Spd Green(light):Valid connection
| |||||
Note: All hardware of this module are ready for active. | ||||||
Aux. DC Voltage Source(Battery simulator) | ||||||
Range | 0~350V @ 140W max | |||||
Accuracy | 0.5%Rg Guar. | |||||
Binary Input | ||||||
Quantity | 8 pairs | |||||
Type | wet/dry, measurement | |||||
Threshold | 10~600Vdc or potential free, Programmable | |||||
Time resolution | 100us | |||||
Debounce time | 0~25ms(Software Controlled) | |||||
Time range | Infinite | |||||
Time errors | ±1ms @ 0.001~1s, ±0.1% @>1s | |||||
Galvanic isolation | 4 isolated with each 2 pairs | |||||
Binary Output(Relay Type) | ||||||
Quantity | 4pairs | |||||
Type | Potential free relay contacts,software controlled | |||||
Break Capacity AC | Vmax: 400Vac / Imax:8A / Pmax:2500VA | |||||
Break Capacity DC | Vmax: 300Vdc / Imax:5A / Pmax:150W | |||||
Binary Output (Semiconductor Type) | ||||||
Quantity | 4pairs | |||||
Type | Open-collector, 14 pin Aviation socket | |||||
Break Capacity DC | 5~15Vdc / 5mA, 10mA max
| |||||
Response time | 100us | |||||
Synchronization | ||||||
Synchronization Mode | GPS, SMA type antenna connector / IRIG-B / FT3 IEEE1588 | |||||
Power supply & Environment | ||||||
Nominal Input Voltage | 100~240Vac | |||||
Permissible Input Voltage | 85~264Vac, 125~350VDC | |||||
Nominal Frequency | 50/60Hz | |||||
Permissible Frequency | 45Hz~65Hz | |||||
Power Consumption | 1500 VA max | |||||
Connection Type | Standard AC socket 60320 | |||||
Operating Temperature | -10℃~55℃ | |||||
Storage Temperature | -20℃~70℃ | |||||
Humidity | <95%RH, non-condensing | |||||
Others | ||||||
PC Connection | RJ45 Ethernet, 10/100/1000M | |||||
Grounding Terminal | 4mm banana socket | |||||
Weight | 18Kg | |||||
Dimensions(W×D×H) | 468×375×164(mm) |
DC Measurement Input (Transducer calibrator)
◆ Voltage input
Range: 0~±10V dc
Max Input: ±11V dc
Accuracy: <0.02% rg Typ. / <0.05% rg Guar.
Input Impedance: 1M ohm
◆ Current Input
Range: 0~±1mA / 1~20mA, auto range
Max Input: 600mA
Accuracy: <0.02% rg Typ. / <0.05% rg Guar.
Input Impedance: 15 ohm
AC / DC Measurement Input( Standard meter )
◆ Input Quantity: 8 channels (blend with binary input pairs).
◆ Voltage rang: 0~600Vrms (Rg: 0.1V,1V,10V,60V,600V).
◆ Voltage accuracy: <0.1% Rg
◆ Current range: 0~5Arms (Clamp input, 30Arms optional).
◆ Current accuracy: <0.1% Rg.
◆ Sample rate: 10KHz.
◆ Input impedance: 600KΩ
◆ Frequency range: 45~65Hz, Accuracy<0.01Hz.
◆ Phase accuracy: 0~360°,<0.2° Typ.
Transient Recorder
◆ Input Quantity: 8 input channels (blend with binary input pairs).
◆ Recorder time: Max 50 Sec.
Energy Meter Calibration
◆ Sensor Usage: Mechanical meters / Electronic meters.
◆ Sensor Output: High level : >4.5V, Low level: <0.2V.
◆ Pulse Input: 1 pulse input port.
◆ Pulse Range: 500KHz pulse input Max.
◆ Pulse Output: 1 Transistor output, Open-collector, 5-15Vdc/5mA.
Kingsine Electric Automation Co., Ltd.
Who am I ?
Since its establishment in 1999, Kingsine Electric Automation Co., Ltd. has focused on researching and developing, producing, and selling Protection Relay Test Sets, CT Analyzers, Reference Power Sources and Calibrators, Voltage and Current Amplifiers, Electricity Monitoring Systems, and Instrumentation. To date, Kingsine's products have been recognized by customers in more than 80 countries worldwide. We regularly participate in large-scale power and energy exhibitions worldwide, including in the United States, Italy, France, Poland, Australia, Dubai, Turkey, Brazil, Philippines, Malaysia, Indonesia, South Africa, Egypt, and other countries, and have received widespread acclaim.Our protection relay testing equipment is compatible with world-renowned relay protection devices such as ABB, SIEMENS, ALSTOM, MITSUBISHI, Schneider, AREVA, SEL, GE, and others. Kingsine Electric has also established a distribution network with partners in the Americas, Europe, Asia, the Middle East, and other countries to provide comprehensive services.
Kingsine is a core supplier to China's State Grid
The facts demonstrate that China's annual power generation has remained the world's number one, with a projected power generation of 840 billion kilowatt hours in 2022, compared to the United States' projected 430 billion kilowatt hours in the same year. China has built the world's most advanced power transmission system for DC current at 1100KV ultra-high voltage levels and more than 11,000 digitized substations based on the IEC61850 standard. China's power grid has the largest, most advanced, safest and most stable power system in the world. We are honored to be the core supplier for State Grid Corporation of China.
Where did I come from?
Kingsine Electric is located in Shenzhen, the "Innovation Capital of China". We have also established subsidiaries in Canada and Hong Kong. Shenzhen is a benchmark city for the development of China's high-tech industry and is home to leading Chinese companies in various industries. Many of China's top companies, including Huawei, the world's largest communication company; DJI, the world's largest commercial drone company; BYD, the world's largest electric vehicle company (which sold 1.86 million electric vehicles globally in 2022, surpassing Tesla's sales of 1.37 million); and Tencent, one of China's leading internet companies, are based in Shenzhen. Excellent enterprises can influence each other, and as the world's factory, Shenzhen has a highly advanced and comprehensive industrial chain, which provides a reliable guarantee for Kingsine Electric to develop, produce, and manufacture high-tech, high-quality, and reliable products.
Where am I going?
Philosophy
Adhering to the belief of novelty in technology and detail in service, and gradually establishing a global service and sales network with worldwide partners and distributors, Kingsine shall spare no effort to serve customers worldwide with innovative technology, reliable products, and quality online service, making electric testing easier across the world.
Business Principles
Kingsine's business principle is to create value for customers, which is reflected in three aspects.
Firstly, Kingsine uses advanced technology to create powerful product features that offer customers a great operating experience.
Secondly, Kingsine provides high-quality products and services at reasonable prices, ensuring that customers receive high value for their investment.
Thirdly, Kingsine emphasizes reliability and after-sales service, providing quality assurance through lean production and ensuring that products have over 15 years of service life and three years of warranty. Kingsine's after-sales maintenance principle is based on cost accounting, ensuring that after-sales service remains efficient and affordable.Based on our modular product design philosophy, and with the help of efficient video diagnostics, our target for after-sales maintenance service is to complete repairs within 20 days.