AC Bypass input RS485 Communication Function DC / AC 1000VA Sine Wave Inverter Flush Mounting Power Supply
1. Product Description
GPDA1000VA-F is one kind of two outputs, with AC bypass input, with 485 communication function DC / AC 1000VA sine wave inverter flush mounting power supply, the entire power supply using the latest circuit design, compact structure, reliable performance, high output efficiency. Entire power in strict accordance with safety requirements designed to meet the IT equipment safety standards.
2. Electrical Specifications
Input | ||||||
Parameter | Min. | Typical | Max. | Unit | Note | |
DC input | DC operating voltage range | 40 | 60 | Vdc | ||
Input rated voltage | 48 | Vdc | ||||
Input Rated Current | 30 | A | Rated input, rated output | |||
Power input Max Surge Current | 45 | A | ≤ 150% of rated current | |||
AC input | AC operating voltage range | 175 | 265 | Vac | ||
Input rated voltage | 220 | Vac | ||||
Input Rated Current | 5 | A |
Export | ||||||
Parameter | Min. | Typical | Max. | Unit | Note | |
The inverter output | Rated output voltage | 220 | Vac | Enter the full voltage range | ||
Rated output current | 4.6 | A | ||||
Output voltage accuracy | ±5 | % | Enter the full voltage range | |||
Rated output frequency | 49 | 50 | 51 | Hz | ||
Rated Capacity | 1000 | VA | ||||
Rated output power | 1000 | W | ||||
Overall efficiency | 85 | % | Rated operating conditions | |||
Output power factor | 0.8 | Rated operating conditions | ||||
Dynamic transient recovery time | 60 | ms | ||||
Waveform | Sine wave THD <3% (linear load) | |||||
Sine wave THD <8% (linear load) | ||||||
Overload | 105~ 125% for not less than 10 minutes to 125 to 150% for not less than 10 seconds. | |||||
Output current crest factor | 3: 1 | |||||
Output | Two AC output | |||||
AC bypass output | Output voltage range | 175 | 265 | Vac | With the AC input voltage changes | |
Rated output voltage | 220 | Vac | ||||
Rated output current | 5 | A | ||||
Switch to mains inverter output time | 10 | ms | Rated load | |||
Mains to inverter output time | 10 | ms | Rated load | |||
Output | Total output of the inverter, the inverter when an input under voltage, overvoltage, fan failure, over-temperature protection, switching to bypass output. |
Protection | ||||||
Parameter | Min. | Typical | Max. | Unit | Note | |
Inverter part | DC input voltage protection point | 36 | Vdc | Enter under voltage protection, the inverter output bypass switch. | ||
DC input voltage recovery point | 40 | Vdc | Achieve recovery value, one minute to restore the inverter output. | |||
DC input voltage recovery hysteresis | 2 | Vdc | ||||
DC input voltage protection point | 66 | Vdc | Enter overvoltage protection, the inverter switch to bypass the output. | |||
DC input overvoltage recovery point | 60 | Vdc | Achieve recovery value, one minute to restore the inverter output. | |||
DC input overvoltage recovery hysteresis | 2 | Vdc | ||||
Input over current protection | Power supply with input over current protection, can not be automatically restored. | |||||
Over Temperature Protection | Power supply with over-temperature protection. When inside the main heat sink temperature is too high, over-temperature protection point reached, the inverter output bypass switch, temperature hysteresis of 10℃ or so. | |||||
Anti-reverse protection | Power supply with input anti-reverse protection. When reversed, the power does not work, and no damage. | |||||
Short circuit protection | Power supply with short circuit protection. When the power fails short intervals of one minute start time, 6 minutes lift failure, can be recovered. Long-short, the power shutdown, the short is removed, you can manually re-boot after work. | |||||
Output over current protection | Power supply with over current protection. Detect over current, output power is turned off, every one minute start time, when the load back to the ratings, self-recovery. Long-term overload, power off, you can manually reboot after work. | |||||
Alarm (buzzer alarm) | DC input error, overload, short circuit, inverter fault, the buzzer alarm. | |||||
AC bypass section | Input over current protection | Bypass input section having an input over current protection function (≥ 10 A), non-self-recovery. The need to manually replace the fuse before working again. |
Environment | |||||
Parameter | Min. | Typical | Max. | Unit | Note |
Operating ambient temperature | - 20 | +5 5 | ° C | ||
Inverter temperature storage environment | - 25 | +70 | ° C | ||
Relative humidity | 0 | 95 | % | Relative humidity, dew does not pour | |
Altitude | 15 00 | m | Meet derating requirementsGB3859.2-93 | ||
Cooling | Natural air. With the power of wind turbines internal temperature rises enhanced, cold heat. | ||||
Work Environment | No conductive dust explosion, corrosion and destruction of gases and vapors, no severe vibration and shock |
5. Product Dimensions
6. Product Pictures
Tianjin Estel Electronic Science and Technology Co.,Ltd
Introduction
Tianjin Estel Electronic Science and Technology Co., Ltd (ESTEL(GUANGDONG)TECHNOLOGY CO., LTD), located in China, is a professional supplier of integrated outdoor telecom cabinet and temperature control solutions for outdoor telecom base station. As a science and technology innovative company, we engage in the R&D, manufacture, and sales of telecommunication equipment. Estel has a well-established team of technical and management experts who can meet customers’ specific needs accurately.
The base station integrated solutions and products include outdoor integrated telecom equipment cabinet, battery cabinet, RRU cabinet, power supply cabinet, environment monitoring system, TEC peltier air conditioner, AC220V compressor air conditioner, DC48V variable frequency air conditioner, heat exchanger, rectifier, UPS, embedded telecom power system etc. All the above solutions and products can be custom made.
Our products and solutions have been deployed all over China. Our main domestic customers are China Telecom, China Mobile, China Unicom, State Grid, Shenzhen / Beijing Metro and Huawei / ZTE etc. In addition, our products have been exported to Europe, North America, South America, Central America, Southeast Asia, Africa, Australia, Mid East countries, etc.
“ Customers First, Quality First ” is always our principle. We have attained many certifications, such as ISO9001, ISO14001, OHSAS18001, CE, UL, FCC etc. AS a telecom integrated solutions / energy saving system integrator in China, We have strong advantages in technology competitiveness, management competitiveness ,service competitiveness and price competitiveness. Through many years of experiences in design, production and implementation of different projects around the world, we have gained great reputation. Relying on professional technique and strict quality control, we will continuously offer high cost-effective products and solutions to our respectable customers globally. We will always try our best to meet customers’ need and requirement.
Company Capability
Trade & Market
Main Markets | Total Revenue (%) |
Domestic Market | 50.00% |
Africa | 15.00% |
Southeast Asia | 10.00% |
South America | 5.00% |
Central America | 5.00% |
Australia | 3.00% |
Mid East | 3.00% |
North America | 2.00% |
Southern Europe | 2.00% |
Eastern Europe | 1.50% |
Northern Europe | 1.00% |
Western Europe | 1.00% |
South Asia | 1.00% |
Eastern Asia | 0.50% |