PMC96S meter is a multi-functional power monitoring meter, it
combines function of collecting data and control, and it can
replace many kind of meters, relays, transformers and others
components. PMC96S can be installed in different positions of
electricity distribution system.
PMC96S is designed with RS-485 communication interface, which
enable itself to be integrated into a variety of power monitoring
systems. Data acquisition and remote control can be easily
performed through the supporting management software or other
industrial configuration software.
PMC96S is a true RMS-based measuring meter that can accurately
measure highly nonlinear loads. Its advanced grid frequency
synchronization sampling technology enables it to accurately
measure a variety of power parameters, including voltage/current
RMS, frequency, active power, reactive power, apparent power, power
factor, input/output active energy, total active energy,
Input/output reactive power, total reactive power, apparent power,
voltage total harmonic distortion (THD), 1~31 voltage harmonics,
current total harmonic distortion (THD) and 1~31 current harmonics,
etc. . All measurements, min and max, and demand measurements can
be viewed on the display or remotely using the software.
Overview of Meter functions
Table 1
Host function and characteristic |
Transient true RMS value |
Current Each single phase and combined phase, average value |
Phase voltage/Line voltage Each single phase and combined phase, average value |
Active, reactive, apparent power Sum of each single-phase and three-phase |
Power factor Sum of each single-phase and three-phase |
Frequency 45~65Hz |
MIN/MAX VALUE |
MIN/MAX CURRENT RMS |
Maximum/minimum phase voltage RMS |
Maximum/minimum total active, reactive, apparent power |
Max/Min total power factor |
Max/Min Frequency |
Max/Min THD I和THD U |
Demand and peak value |
Current per phase the present value/peak value/monthly peak value |
Total active power, total reactive power, total apparent power the present value/peak value/monthly peak value |
Energy |
Input/ output/ active electric energy 1 channel pulse output Input output active electric energy 1 channel pulse output |
Input/ output/ reactive electric energy 1 channel pulse output active electric energy 1 channel pulse output |
apparent power |
monthly energy |
Electric energy multi-rate |
8 multi-rate time, 4 rates can be set |
Power quality |
THD current and voltage |
1-31 times harmonic analysis |
Voltage crest factor CF and current K factor |
Event record |
100pcs SOE event record |
Warning alarm system |
8 warning channels with configurable limit value |
4 warning channels with configurable logic |
Communication |
RS-485 /MODBUS-RTU Protocol |
Display |
Large screen STN liquid display |
Real time clock |
Year, month, date, minute, second |
Others |
Support program online upgrade |
Table 2
Auxiliary module features |
Analog I/O (DI) input module (optional) |
2-channel Analog I/O input |
Relay (DO) output module (optional) |
2-channel relay output, which can be set by local over-limit alarm or by remote control |
Analog input (AI)/output (AO) module (optional) |
2 Channels in total Being optional for 4-20mA DC analog input, 0-5V DC analog input, 4-20mA DC analog output The first analog port (A1 port) is located at the same (DI) port of Binary Input, so user only can select either one of the two but can’t select both |
Technical indicators
Electrical characteristics | ||
Measure type | 3P3W AC system, 3P4W AC system; | |
Samping rate | 128 points per cycle | |
Data refresh rate | 1S | |
Measure accuracy | Cureen | ±0.2%FS |
Voltage | ±0.2%FS | |
Power | 0.5S | |
Frequency | ±0.001Hz | |
Active Energy | 0.5S | |
Reactive Energy | 1.0S | |
DC input(AI) | 0.5% FS | |
DC output(AO) | 0.5% FS | |
Input voltage characteristics | Measure Voltage | 3 *220/380V(Directly input) |
3 * 57.7/100V(PT secondary side) | ||
Allowed overload capability | 1.2times / continuous | |
input resistance | 300KΩ/phase | |
Input current characteristics | Measure current | 5A (CT Secondary side)Or 1A (CT Secondaryside) |
Allowed overload capability | 1.2 times/continuous | |
input resistance | <0.1Ω | |
Binary input | Working voltage | 15 VDC |
input resistance | 12KΩ | |
Isolation voltage | 2KV | |
Relay Output | Node type | Mechanical contact |
Node capability | 220 VAC/5A,30 VDC/5A | |
4-20mA DC input measurement | Measure current | 4-20mA |
Allowed overload capability | 1.2 times / continuous | |
input resistance | 10Ω | |
Isolation voltage | 2KV | |
0-5V DC input measurement | Measure Voltage | 0-5V |
Allowed overload capability | 1.2times / continuous | |
input resistance | 12.5KΩ | |
Isolation voltage | 2KV | |
4-20mA DC output | Open-circuit Voltage | 15VDC |
Load capability | ≤600Ω | |
Isolation voltage | 2KV | |
Power supply | AC | 85~264 VAC/45-65Hz |
DC | 100~375 VDC | |
Power consumption | < 3W | |
Mechanical performance | ||
Weight | 0.5kg | |
IP Protection Level | Meter Panel IP52,Meter Host IP30 | |
Dimension | Host | 96 X 96 X 72 mm |
Host+modules | 96 X 96 X 120 mm | |
Working temperature | Display screen | -20~70℃ |
Meter | -25~70℃ | |
Storage temperature | Meter+display screen | -40~85℃ |
Relative humidity | 5% - 90%RH, No condensation | |
EMC | ||
Antistatic discharge interference | IEC 61000-4-2,Level 4 | |
Anti-fast transient group pulse | IEC 61000-4-4,Level 4 | |
Anti-surge | IEC 61000-4-5,Level 3 | |
Resistance to power frequency magnetic field | IEC 61000-4-8,Level 3 | |
Electrical insulation performance | ||
Insulation resistance | GB/T13729,>50MΩ | |
Power frequency withstand Voltage | GB/T13729,AC 3KV 50Hz /1min | |
Impulse voltage | GB/T13729,5KV,1.2/50us |
Model specification::PMC96S-①-②-③-④-⑤ | |
① Model code: | |
1 | 57.7/100V Rated measurement voltage,5A Rated measurement current. |
2 | 57.7/100V Rated measurement voltage,1A Rated measurement current. |
3 | 220/380V Rated measurement voltage,5A Rated measurement current. |
4 | 220/380V Rated measurement voltage,1A Rated measurement current. |
② Model code: | |
1 | Power supply:85~264 VAC/45-65Hz,100~300 VDC . |
③ Model code: | |
0 | Without DI |
2 | 2 Channels DI |
④ Model code: | |
0 | Without relay output |
1 | Optional 1 channel relay output(RL1+,RL1- port) |
2 | Optional 2 channels relay output |
⑤ Model code: | |
ab | ab is a 2 integer,a means AI01 port optional for AI/AO modules, b
means AI02portoptional for AI/AO 0 –none 1 - 0-5V DC analog input measure(AI) 2 - 4-20mA DC analog input measure(AI) 3 - 4-20mA DC analog output(AO) For example:ab = 00,meansnot equipped with AI/AOmodule ab = 21,Means AI01 port is equipped with 0-5V DC analog input measureAI/AOmodule, AI02 port is equipped with 4-20mA DC analog input measureAI/AOmodule |
Kingsine Electric Automation Co., Ltd.
Who am I ?
Since its establishment in 1999, Kingsine Electric Automation Co., Ltd. has focused on researching and developing, producing, and selling Protection Relay Test Sets, CT Analyzers, Reference Power Sources and Calibrators, Voltage and Current Amplifiers, Electricity Monitoring Systems, and Instrumentation. To date, Kingsine's products have been recognized by customers in more than 80 countries worldwide. We regularly participate in large-scale power and energy exhibitions worldwide, including in the United States, Italy, France, Poland, Australia, Dubai, Turkey, Brazil, Philippines, Malaysia, Indonesia, South Africa, Egypt, and other countries, and have received widespread acclaim.Our protection relay testing equipment is compatible with world-renowned relay protection devices such as ABB, SIEMENS, ALSTOM, MITSUBISHI, Schneider, AREVA, SEL, GE, and others. Kingsine Electric has also established a distribution network with partners in the Americas, Europe, Asia, the Middle East, and other countries to provide comprehensive services.
Kingsine is a core supplier to China's State Grid
The facts demonstrate that China's annual power generation has remained the world's number one, with a projected power generation of 840 billion kilowatt hours in 2022, compared to the United States' projected 430 billion kilowatt hours in the same year. China has built the world's most advanced power transmission system for DC current at 1100KV ultra-high voltage levels and more than 11,000 digitized substations based on the IEC61850 standard. China's power grid has the largest, most advanced, safest and most stable power system in the world. We are honored to be the core supplier for State Grid Corporation of China.
Where did I come from?
Kingsine Electric is located in Shenzhen, the "Innovation Capital of China". We have also established subsidiaries in Canada and Hong Kong. Shenzhen is a benchmark city for the development of China's high-tech industry and is home to leading Chinese companies in various industries. Many of China's top companies, including Huawei, the world's largest communication company; DJI, the world's largest commercial drone company; BYD, the world's largest electric vehicle company (which sold 1.86 million electric vehicles globally in 2022, surpassing Tesla's sales of 1.37 million); and Tencent, one of China's leading internet companies, are based in Shenzhen. Excellent enterprises can influence each other, and as the world's factory, Shenzhen has a highly advanced and comprehensive industrial chain, which provides a reliable guarantee for Kingsine Electric to develop, produce, and manufacture high-tech, high-quality, and reliable products.
Where am I going?
Philosophy
Adhering to the belief of novelty in technology and detail in service, and gradually establishing a global service and sales network with worldwide partners and distributors, Kingsine shall spare no effort to serve customers worldwide with innovative technology, reliable products, and quality online service, making electric testing easier across the world.
Business Principles
Kingsine's business principle is to create value for customers, which is reflected in three aspects.
Firstly, Kingsine uses advanced technology to create powerful product features that offer customers a great operating experience.
Secondly, Kingsine provides high-quality products and services at reasonable prices, ensuring that customers receive high value for their investment.
Thirdly, Kingsine emphasizes reliability and after-sales service, providing quality assurance through lean production and ensuring that products have over 15 years of service life and three years of warranty. Kingsine's after-sales maintenance principle is based on cost accounting, ensuring that after-sales service remains efficient and affordable.Based on our modular product design philosophy, and with the help of efficient video diagnostics, our target for after-sales maintenance service is to complete repairs within 20 days.