LXC31X0 Series Diesel Generator Control Panel 32 Bit Arm Processor
1. Summary
LXC31X0 Series automation controller uses 32-bit ARM processor, the
module is realized intelligent
generator control technology.There are used for genset automation
and monitor control system of single
unit to achieve automatic start/stop, data measurement, alarm
protection.It fit with LCD display, optional
languages interface (Chinese, English, Spanish and Russian), and it
is reliable and easy to use.It’s
achieve a precision measuring,fixed value adjustment, time setting
and set value adjusting and etc.All
parameters can be configured from front panel or through
programmable USB interface via PC. It can
be widely use in all types of automatic genset control system with
compact structure, advanced circuits,
simple connections and high reliability.
2. Performance and characteristics
LXC31X0 series controller has two types:
LXC3110:ASM (Automatic Start Module),it controls generator to
start/stop by remote signal;
LXC3120:AMF (Auto Mains Failure), updates based on LXC3120,
moreover, has mains electric quantity
monitoring and mains/generator automatic transfer control function,
especially for automatic system
composed by generator and mains.
Its main features are as follows:
Display:132×64 LCD with emerald green backlight;
Language:Chinese, English, Spanish and Russian;
Operating:good feeling button pushing, long button life;
Suitable for:3-phase 4-wire, 3-phase 3-wire, single phase 2-wire,
and 2-phase 3-wire systems with
voltage 120/240V and frequency 50/60Hz.
Detection parameters:
Load:
Current IA,IB,IC
Active Power (KW)
Reactive Power (KVar)
Apparent Power (KVA)
Power Factor (PF)
Accumulated Energy (kWh)
Mains Monitor:With over voltage, under voltage, over frequency,
under frequency, loss phase and
reverse phase function;
Gens Monitor:With over voltage, under voltage, over frequency,
under frequency, loss phase and
reverse phase function;
Acquisition parameters:
Temp. (WT) °C/ °F both be displayed
Oil pressure (OP) kPa/Psi/Bar all be displayed
Engine Speed (RP) RPM (Unit)
Battery Voltage (VB) V (unit)
Charger Voltage (VD) V (unit)
Hours counter (HC): Max. 999999 hours
Start times: Max.999999 times
Protection: Automatic start/stop of the genset, ATS(Auto Transfer
Switch) control with perfect fault
indiCAT-parts-partsion and protection function;
Output Control:With ETS, idle control, pre-heat control, speed
raise control and speed drop control,
All output ports are relay-out;
Parameter Settings:All the parameters can be adjusted using front
panel of the controller or use the
computer through USB to connect directly to controller settings,
all is not lost when power down
parameter system;
Sensor Detection:More kinds of curves of temperature, oil
pressure, fuel level can be used directly
and users can define the sensor curves by themselves;
Multiple Crank Disconnect Conditions:Gens frequency,speed,oil
pressure,D+;
Widely Power supply range: DC(8~35)V, suitable to different start
battery voltage environment;
Mounting Assembly:Modular design, anti-flaming ABS plastic
enclosure, plug gable connection
terminals and embedded installation way; compact structure with
easy mounting.
3. SpecifiCAT-parts-partsion
4. Operation
4.1. Push buttons
4.2. IndiCAT-parts-partsor light
LXC3110 Panel IndiCAT-parts-partsors
4.3. Automatic start/stop operation
Auto mode is selected by pressing the button; a LED besides the
button will illuminate to confirm the
operation.
4.3.1. Auto Start Sequence,
LXC3120:When mains is abnormal (over/under voltage, loss of
phase), enter into “Mains Abnormal
Delay” and LCD displays count down time. When the delay is over,
“Start Delay” timer is initiated.
LXC3110:When “Remote Start” is active, “Start Delay” timer is
initiated.
“Start Delay” countdown will be displayed on LCD.
When start delay is over, preheat relay energizes (if
configured), “preheat delay XXs” information will
be displayed on LCD.
After the above delay, the Fuel Relay is energized, and then one
second later, the Start Relay is
engaged. The engine is cranked for a pre-set time. If the engine
fails to fire during this cranking
attempt then the fuel relay and start relay are disengaged for the
pre-set rest period; “crank rest time”
begins and wait for the next crank attempt.
Should this start sequence continue beyond the set number of
attempts, the start sequence will be
terminated, the first line of LCD display will be highlighted with
black and Fail to Start fault will be
displayed.
In case of successful crank attempt, the “Safety On” timer is
activated, allowing Low Oil Pressure,
High Temperature, Under speed, Charge Alternator Failure and Aux.
inputs (configured) to stabilize
without triggering the fault. As soon as this delay is over, “start
idle” delay is initiated (if configured).
During “start idle” delay, under speed, under frequency, under
voltage alarms are inhibited. When this
delay is over, “warming up” delay is initiated (if configured).
After the “warming up” delay, if generator status is normal, its
indiCAT-parts-partsor will be illuminated. If generator
voltage and frequency have reached on-load requirements, then the
generator close relay will be
energized; genset will take load; generator power
indiCAT-parts-partsor will illuminate and generator will enter into
Normal Running status. if voltage or frequency is abnormal, the
controller will initiate shutdown alarm
(alarm information will be displayed on LCD).
4.3.2. Auto Stop Sequence,
LXC3120:During normal running process, if mains normal, enters
into “Mains Normal Delay”. When
mains indiCAT-parts-partsor illuminates, “Stop Delay” begins.
LXC3110:When the “Remote Start” signal is removed, the stop delay
is initiated.
Once this “stop delay” has expired, the Generator Breaker will
open and the “Cooling Delay” is then
initiated. After “Transfer Delay”, the mains close relay will be
energized; mains will take load;
generator power indiCAT-parts-partsor will extinguish while mains
power indiCAT-parts-partsor will illuminate.
During “Stop Idle” Delay (if configured), idle relay is
energized.
“ETS Solenoid Hold” begins, ETS relay is energized while fuel
relay is de-energized.
"Fail to Stop Delay" begins, complete stop is detected
automatically.
Generator is placed into its standby mode after its complete
stop. Otherwise, fail to stop alarm is
initiated and the corresponding alarm information is displayed on
LCD
4.4. Manual start/stop operation
LXC3120:Manual mode is selected by pressing the button; a LED
besides the button will
illuminate to confirm the operation.
Press key, select “Mode Select”, then choose “Test Mode”. Under
the two modes,
press button to start the genset, it can automatically judge crank
success and accelerate to high
speed running. If high temperature, low oil pressure, over speed
and abnormal voltage occur during
genset running, controller can effectively protect genset to stop.
Under Manual Mode, if mains normal,
load breaker won’t transfer; if mains abnormal, load breaker will
transfer to generator. Under Test
Mode, after genset high speed normal running, no matter mains
normal or not, load will be transferred
to generator.
LXC3110:Manual mode is selected by pressing the button; a LED
besides the button will
illuminate to confirm the operation; Then press button to start the
generator, it can automatically
judge crank success and accelerate to high speed running. If high
temperature, low oil pressure, over
speed and abnormal voltage occur during genset running, controller
can effectively protect genset to
stop. After genset high speed normal running, controller will send
Gen Closed signal.
Manual stop: pressing key can shut down the running genset.
Guangdong ALI Testing Equipment Co,.Ltd
Since establishment in 1985, Guangdong ALI Testing Equipment Co., Ltd, a wholly-owned subsidiary of GSKA Group has been providing a wide and complete range of products and services to the society. GSKA has now 16 offices, warehouses and service centres in China, with head office loCAT-partsed in Hong Kong. There are more than 100 employees in GSKA Group, and we are expanding into many industries with rapid expanding pace of China.
There are mainly 4 departments in GSKA Group, namely:
1) Construction and Mining equipment
GSKA has been cooperating with many international famous brands in
China, such as Ingersoll-rand, Atlas Copco and Liebherr. Our
products include concrete batching plants, concrete mixers,
hydraulic crawler drills, pneumatic crawler drills, water well
drills, air compressors, road compactors, breakers and various
other equipment. We are major in several industries, such as
hydro-electric power plants, cement quarries, coal mines and
railway systems.
In order to provide a quick response to our customers, we have stocked over US$1.5 Million spare parts of Ingersoll-rand and Atlas Copco in our Chinese warehouse. Recently, we have exported small air compressors, pneumatic crawler drills, water well drills and drilling accessories and spare parts to overseas market.
2) Power Group
GSKA has been supplying CAT-parts and Broadcrown gensets for more than
15 years. Our major customers include Telecoms, Banks, Airports,
Factories and many other sectors in the society. We are also doing
assembly of gensets in China, under our brand name of "GSKA " with ratings from 1KVA to 2000KVA. The quality of "GSKA " genset has won a very good reputation from customers in China and
overseas market.
We are also the specialists for genuine spare parts, such as CAT-parts, Perkins, FG Wilson, Cummins, , Volvo, etc.
Besides gensets, we also provide total solution on the power problems, such as Powerware - UPS, DC system and battery ,lightning equipment and many other electronic products.
3) Security and IT Group
GSKA acquired famous USA brand name Locktronix in 2004 and started
manufacture electric locks in China. Since then, we have been
exported products to the Middle East, South Asia and Africa. Our
market is expanding each year and we are looking for more
distributors in different countries to be our business partners.
Besides electric locks and accessories, we have also developed our
own access control system by our software team. The system includes
smart card solution and also biometric access control, such as
hand-key, fingerprint and facial recognition. Our EC-PAYROLL system
has been widely used in many factories both in Hong Kong and
mainland China.
After all, GSKA has an objective of "Always Provide the Best" and we shall consistently provide high quality products and reliable services to our worldwide customers. We are looking forward to making good business with our partners